Renaissance Masonry Units
Dedicated To Fostering A Renaissance Of Stone Use
THE SOLID FACTS
RENAISSANCE STANDS ALONE: Nothing compares to the quality, durability and acceptance of Renaissance Masonry Units. Since 1956, a cement-free process has been used to replicate limestone. This process chemically fuses the major components of limestone, under intense heat and pressure, to form a highly dense, fine grain natural building stone.
THE GOODS: Renaissance Stone continues to be both a design and job site favorite. Proven ease of installation and clean-up using standard masonry practices add up to generous cost savings over quarried stone and precast. Installation is the same as brick. The use of standard masonry wall ties, mortar, flashing, expansion joints, ect., make installation an efficient and simple concept.
Colors and Textures
Custom colors are available to suit architectural selection in quantities of 1,000 square meters (10,000 square feet) or more. Textures include smooth, rocked, press hammered, dressed, chamfered, press hammered with a draft margin and rocked with a draft margin.

| Bluegrass
| 
| | Cinnamon*
| | Nutmeg*
| | Olive
| | Paprika
| | Sage
| | Taupe*
| | Wheat*
| | White*
|
|
U.S. STANDARD SIZES |
| Dimensions |
RS115 |
RS758 |
RS358 |
|
Height
Length
Bed
Weight*
|
11 5/8"
23 5/8"
3 5/8"
75.2 lbs
|
7 5/8"
23 5/8"
3 5/8"
49.3 lbs
|
3 5/8
23 5/8"
3 5/8"
23.5 lbs
|
|
*Weight varies according to finish.
|
COMPARE AND SAVE:
| Physical Properties of Renaissance Masonry Units and Comparative Dimension Stone Standards |
Physical Property |
Renaissance Masonry Units Range* of Average Values |
Limestone ASTM C568 |
Quartz-Based ASTM C616 |
| Class I |
Class II |
Class III |
Class I |
Comprehensive Strength Brick Method CSA A82.2/ASTM C67 MPa (psi) |
50-68 (7252-9863) |
This compressive strength range is provided for comparison to brick products. ASTM C67 and CSA A82.2 methods are specifically for brick products. Compression test results obtained using these methods differ from those using the C170 Dimension Stone method. |
Compressive Strength Dimension Stone Method ASTM C170 MPa (psi) |
38-53 (5512-7687) |
minimum 12 (1800) |
minimum 28 (4000) |
minimum 55 (8000) |
minimum 13.8 (2000) |
Absorption ASTM C97 % |
7.8-9.8 |
maximum 12 |
maximum 7.5 |
maximum 3 |
maximum 20 |
Density ASTM C97 kg/m3 (lb/ft.3) |
2020-2120 (126-132) |
minimum 1760 (110) |
minimum 2160 (135) |
minimum 2560 (160) |
minimum 2160 (135) |
Modules of Rupture ASTM C97 MPa (psi) |
4.3-6.3 (624-914) |
minimum 2.9 (110) |
minimum 3.4 (500) |
minimum 6.9 (1000) |
minimum 2.1 (300) |
THE FINAL WORD: Architects throughout the U.S. and Canada have found Renaissance Stone to be a durable, high quality building material which offers design flexibility at significant budget savings. Whether your design calls for accents or a complete wall cladding of stone, Renaissance is the solid choice. See for yourself!
Home
About Building Stone |
Renaissance Masonry Units |
Project Gallery |
Contact Us
|